Compressor Silencers

Compressor silencers and inline compressors silencers are often specified for centrifugal and axial compressors which create broad spectrum noise with peaks at the blade passing frequencies. In addition many piping systems suffer from propagation of low frequency noise both within the gas stream and along the pipewall, which if not effectively attenuated can result in the acoustic performance of the silencer being compromised. The custom designed Flo-Dyne compressor inline silencer will treat these special noise problems to give a highly effective silencing solution.

The blade passing frequency of a high speed centrifugal or axial compressor will often fall somewhere within the 1KHz to 4KHz octave bands. The frequencies within these octave bands result in wavelengths which are comparitively short especially when contrasted with the wavelengths of the low frequency noise which propagates along the pipewall.

[compressor in-line silencer] Optimum design of a compressor silencer requires not just an engineering solution to the acoustic baffle as well as the containing shell.

Flo-Dyne engineers will custom design the entire acoustic baffle and the containing shell providing an optimum total silencing solution thereby ensuring that the silencer is at its most effective during operation. 

Failure to provided the correct balance of:

Fibre diameter; 
Fibre Bulk density;
Fibre composition;
Perforated plate hole diameter;
Perforated plated hole spacing;
Perforated plate thickness;
Flow passage configuration;
Flow passage width / length
Packing depth;
Packing protection measures, mesh / cloth screen properties;

Will result in poor acoustic performance and high pressure drops.

[compressor silencer on test] In-line compressor silencer being prepared for its hydraulic proof test.

This silencer was designed for operation at 200 BarG and to provide a guaranteed 20 dB(A) overall attenuation with specific attenuations specified for each octave band from 63hz through to 8KHz.

 
Send Email

 
  CONTACT US AT
FLO DYNE CONTROLS INDIA P.LTD.
ADDRESS : No.1402, The Corporate Park, Sector 18, Vashi
Santacruz (W), Mumbai-400049 (Maharashtra)


Contact : Swapnil,

Send Email


Send Email

WEBSITE : www.goldenpages.in/flodynecontrols
Contact Person :
Swapnil

Mobile : Send SMS
 
Home | About Us | Products | Contact Us |
 
Copyrights @
Flo Dyne Controls India P. Ltd.
Site Designed & Maintained by Aman Infotech
 
 
Back to Top


Acoustic Filters, Bladder Tanks, Blower Silencers, Compressor Silencers, Compressor Tanks, Control Valve Silencers, Discharge Pulsation Dampener, Exhauster Silencers, Gas Pulsation Analysis, Gas Pulsation Dampeners, High Temperature Exhausts, In Line Silencers Ejectors And Gas Compressors, Pulsation Analysis, Simple Diffuser Silencers, Steam Vent Silencers, Suction Dampeners, Surge Tanks, Vent Silencers And Industrial Silencers